WINIX A230 Air Purifier

SAFETY INSTRUCTIONS
IMPORTANT CAUTIONS FOR USING YOUR AIR PURIFIER:
WARNING: Follow the instructions in this manual to reduce the risk of electric shock, short circuit, and/or fire.
- Do not repair or modify the unit. All repairs should be completed by a qualified technician.
- The plug for this unit is polarized with one blade wider than the other. Do not force the plug into an electrical outlet. Do not alter the plug in any way. If the plug does not fit into the outlet, reverse the plug. If it still does not fit, contact a qualified technician to install a proper outlet.
- Do not use if the power cord or plug is damaged or the connection to the wall outlet is loose.
- Use AC 120V only.
- Do not damage, break, forcefully bend, pull, twist, bundle, coat, pinch, or place heavy objects on the power cord.
- Periodically, remove dust from the power plug. This will reduce the risk of shock due to humidity buildup.
- Remove the power plug from the outlet before cleaning the unit. When removing the power plug, grasp it by holding the plug itself; never hold the cord.
- If the power plug is damaged, it must be replaced by the manufacturer or a qualified technician.
- Remove the power plug from the outlet when not in use.
- Do not handle the power plug with wet hands.
- Do not operate the unit when using indoor smoke-generating insecticides.
- Do not clean the unit with benzene or paint thinner. Do not spray insecticides on the unit.
- Do not use the unit where it is humid or where the unit may become wet, such as the bathroom.
- Do not insert fingers or foreign objects into the air intake or outlet.
- Do not use the unit near flammable gases. Do not use near cigarettes, incense, or other spark-creating items.
- Unit will not remove carbon monoxide emitted from heating appliances or other sources.
IMPORTANT PRECAUTIONS FOR USING YOUR AIR PURIFIER:
- Do not block the intake or outlet vents.
- Do not use near hot objects, such as a stove.
- Do not use where the unit may come into contact with steam.
- Do not use the unit on its side.
- Keep away from products that generate oily residue, such as a deep fryer.
- Do not use detergent to clean the unit.
- Do not operate without a filter.
- Do not wash and reuse the True HEPA Filter.
- Hold the handle on the back of the unit to transport.
- Do not hold the front panel.
- Do not stick any small objects into the air outlet vents or the fan.
SAFETY AND CAUTIONS
Before operating this equipment, carefully read and follow these safety cautions.
- Ensure filters are inserted before running the unit. Running the unit without filters can shorten the lifespan of the unit and cause electric shock or injury.
- Be sure foreign objects are NOT inserted into the vents on the unit. Objects can include pins, rods, and coins.
- Do not touch any part of the interior of the unit with wet hands. The high voltage may cause an electric shock.
- Ensure unit intake and outlet vents do not become blocked. Blockage may lead to increased internal temperatures, causing product failure and deformation.
- Do not use the unit as a step stool or place heavy objects on the unit. Personal injury may occur or a product failure and deformation.
WARNING: Follow these instructions to reduce the risk of serious injury or death and to reduce the risk of damaging the unit.
- If the power cord is damaged, it must be replaced with a special cord. Reassembly is available from the manufacturer or its service agent.
- This appliance is not intended for use by a person (including children) with reduced physical, sensory, or mental capabilities, or a lack of experience and knowledge of the unit, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- This unit is not intended to be used to preserve documents or for art conservation.
- Do not pull on the power cord when unplugging the unit.
- Do not tie or knot the power cord when the unit is in operation.
- If the unit becomes submerged in water, unplug it and contact customer service.
- Do not unplug or move the unit while in operation.
- Do not plug additional appliances into the same outlet or power supply.
- Do not touch the plug with wet hands.
- Unplug the unit when not in operation for extended periods of time.
- Do not place around heating elements.
- Do not use around mist or fumes from industrial oil or around large quantities of metallic dust.
- The cord can become damaged by forcefully bending, pulling, twisting, bundling, pinching, or placing heavy objects on it.
- Do not install in any sort of motor or transport vehicle (trucks, boats, ships, etc.).
- Do not place in an area with excessive amounts of noxious gases.
MODEL PART DIAGRAM
PACKAGE CONTENTS
- Unit
- 360º All-in-One True HEPA Filter
- User Manual
WHERE TO USE
- Allow 12 ~ 18 in. of space between TVs, radios, and other electronics. Electromagnetic interference from certain electronics may cause product malfunction.
- Place indoors away from direct sunlight. Direct exposure may cause product malfunction or failure.
- Only place on hard, flat surfaces. Flimsy or slanted surfaces may result in abnormal noise and vibrations.
- Allow 12 ~ 18 in. from walls. For maximum air flow.
4-STAGE AIR PURIFICATION
Air Purification means it removes inanimate particles
CONTROL PANEL
- Filter Replacement Indicator: LED light indicates when it is time to change the filter.
- Filter Reset Button: After replacing the 360º All-in-One True HEPA Filter, use a small object such as a paper clip to press and hold the Filter Reset Button for at least 5 seconds until the Filter Replacement Indicator turns off.
- Auto Mode Button: The unit will default to Auto with PlasmaWave® enabled when first powered on. Auto Mode automatically adjusts fan speeds according to your indoor air quality. The fan speed will adjust to low when the air quality is good, medium when fair, and high when poor.
- Air Quality Indicator: Color-coded LED light indicates one of three levels of Air Quality: Red (poor), Amber (fair), and Blue (good).
- Sleep Mode Button: When Sleep Mode is activated, the Air Quality Indicator LED light is disabled. Fan speed will automatically set to minimum speed (lower than ‘Low’), which will be nearly silent. When Sleep Mode is active, PlasmaWave® will be disabled, but it can be turned back on.
- PlasmaWave® Button: Enables or disables PlasmaWave®. “When the unit is running, you may hear a chirping or buzzing sound. The sound is from large particles passing through PlasmaWave®, it is normal and does not signify product failure.” Press the PlasmaWave® Technology button when the unit is on to enable or disable this feature.
- Fan Speed Indicator Buttons: Indicates the current fan speed. Use the Fan Speed arrow buttons to set the desired fan speed. Fan speeds cycle over in this sequence: Auto, Low, Medium, High, Auto.
- Power Button: Turns the unit on or off. During the first 30 seconds of power, the Air Quality Indicator will cycle through Blue, Amber, and Red colors. Smart Sensor takes approximately 4 minutes to detect the air quality in the environment before normal operation begins.
INITIAL OPERATION
- Turn the product upside down.
- Grab the handle at the bottom of the product, turn counter-clockwise, and pull out the filter cover.
- Remove the protective vinyl from the filter installed inside the product.
- Install the filter top side down into the bottom of the unit until it is fully inserted. The top of the filter shows the opening, and the bottom of the filter is solid.
- After installing the filter, turn the handle clockwise to close the filter cover.
- Return the product to an upright position and resume normal operation.
MAINTENANCE
When to Replace Filters
- When the Check Filter indicator LED is on, it is time to replace the All-in-One True HEPA Filter.
- Intervals between filter replacement may vary depending on the environment.
REPLACING FILTERS
Resetting Filter Life:
After replacing the 360º All-in-One True HEPA Filter, use a small object such as a paper clip to press and hold the Filter Reset Button for at least 5 seconds until the Filter Replacement Indicator turns off.
CLEANING CARE
Cleaning the Filters:
Clean with a vacuum or a soft brush.
- Only clean the Pre-Filter.
- This filter CAN NOT be washed.
- Intervals between filter cleaning may vary depending on the air quality.
Cleaning the Exterior & Interior:
Wipe with a soft, damp cloth using room temperature water. Afterwards, wipe it down with a clean dry cloth.
After turning the product upside down, remove the filter cover and clean the interior with a vacuum cleaner.
For optimal performance, clean every 14 days.
NOTICE
- When cleaning the unit, always unplug the power cord first and then wait until the unit has cooled down.
- Never disassemble, repair, or modify this unit yourself.
- Do not use flammable sprays or liquid detergents.
- Do not allow children to clean or maintain the unit.
- Before cleaning or maintaining, ensure the unit is unplugged.
- Do not use benzene, alcohol, or other volatile fluids, which may cause damage or discoloration.
UNIT SPECIFICATIONS
- Model Name: A230
- Dimensions: 9.5 in(W) x 9.5 in(D) x 14.6 in(H)
- Power Voltage: AC 120 V / 60 Hz
- Weight: 6.75 lbs
- Power Rate: 55 W
- Replacement Filter FILTER O/SKU: 1712-0110-00
- Verified Room Size: 230 sq ft.
The exterior, design, and product specifications may be changed without prior notice to improve product performance.
Contact Winix for product-related inquiries and customer service
- Dedicated Call Center: (877) 699-4649
- Website: www.winixamerica.com
To expedite service, please specify the model name and number, the nature of the problem, your contact information, and your address.
TWO YEARS WARRANTY
The terms of the warranty are as follows.
- This product is manufactured under stringent quality control and inspections.
- The warranty will be voided if product failure is a result of negligence or misuse by the consumer.
- A proof of purchase must be presented upon claiming a Product Warranty.
- Store the proof of purchase in a safe place or register your product on winixamerica.com to upload your proof of purchase.
- This warranty is valid only in the USA and Canada.
For more information, visit https://winixamerica.com/terms-and-conditions/
For more Manuals by Winix, visit ManualsLibraryy
WINIX A230 Air Purifier-FAQs
How do I reset the filter on the Winix A230?
After replacing the 360° All-in-One True HEPA filter, press and hold the Filter Reset button for about 5 seconds using a paper clip until the indicator light turns off.
Can I leave the Winix A230 running all the time?
Yes. The Winix A230 is designed for 24/7 operation. Continuous use helps maintain clean air, though frequent door or window opening may shorten filter life.
How does the Winix A230 air purifier work?
It pulls air through a pre-filter, carbon filter, and True HEPA filter, then uses PlasmaWave® technology to neutralize pollutants before releasing clean air back into the room.
What is Winix PlasmaWave technology?
PlasmaWave creates positive and negative ions from air moisture. These ions attach to pollutants and break them down safely, without producing harmful ozone.
How often should I change the Winix A230 filter?
For best performance, replace the All-in-One True HEPA filter once every 12 months, depending on air quality and usage.
Can I wash the Winix A230 filter?
The carbon pre-filter is washable, but the True HEPA filter is not. Washing or vacuuming the HEPA filter can damage it and reduce efficiency.
Where should I place the Winix A230 for best results?
Place it in an open area with good airflow, at least 8 inches away from walls or furniture, ideally near a pollution source.
Why is the air quality light red on my Winix?
A red indicator means poor air quality. Increase the fan speed or let the purifier run longer until the air quality improves.
Does the Winix A230 remove dust and allergens?
Yes. The True HEPA filter captures up to 99.97% of particles as small as 0.3 microns, including dust, pollen, pet dander, and smoke.