Powr-Flite PP200-Q02-U Battery Powered Mister

INTRODUCTION
Warranty

Within 30 days of purchase, to activate product warranty, go to: https://www.powr-flite.com/warranty-registration. For warranty information, go to www.tornadovac.com.
Warning Labels

Before operating the Portable Battery Powered Mister, read and understand completely this owner’s manual, paying special attention to warning labels. These labels indicate a potentially hazardous situation that could result in death or serious injury if not avoided. Use only as described in this manual.
Important

There are no owner serviceable parts inside this machine. Removal of screws and accessing internal components will void all warranty claims.
Personal Protection Equipment (PPE)

Personal Protection Equipment (PPE) should be worn during the operation of this machine. Chemicals can remain airborne for some time after application, and therefore, safety glasses and masks are recommended. Gloves should be worn anytime chemicals are handled.
Centers for Disease Control (CDC)

Only products shown on LIST N from the Centers for Disease Control (CDC) should be used through this machine in order to kill viruses, including SARS-CoV-2 (COVID-19). It is important to follow mixture ratios exactly as indicated on the product label. Follow the manufacturer’s recommendation of disposal of all chemicals used in this machine.
POLARIZATION INSTRUCTIONS
Your new Powr-Flite unit is a high-quality, precision-made product. All parts used in the manufacturing of this unit have passed rigid quality control standards before assembly. Please safeguard the original receipt/invoice given at the time of purchase. If you experience any problems with your unit during the warranty period, the original receipt/invoice will act as proof of purchase.
Upon receipt, inspect the outer box for exterior damage. Unpack all internal parts, ensure all items are present according to the owner’s manual, and review components for damage.
Each unit is tested and thoroughly inspected before shipping. If damage is discovered, immediately notify the transportation company that delivered your machine and request an inspection. As a manufacturer, we are unable to act upon any claim for concealed damage, and you must originate the claim. Be sure to keep the carton, packing inserts, and carrier’s receipt until the inspector has verified your claim.

Charger Polarization Instruction
The battery charger is equipped with a 2-wire, polarized AC power cord with one blade wider than the other. This plug fits in the power outlet only one way and is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug still fails to fit, contact an electrician to replace the obsolete outlet. Do not defeat the safety purpose of the polarized plug.
IMPORTANT SAFETY INSTRUCTIONS
Read and understand this owner’s manual and all labels on the unit before operating. Safety is a combination of common sense, staying alert, and knowing how your unit works. To reduce the risk of personal
Injury or damage to your unit: Use only as indicated in this manual.
IMPORTANT:
The manufacturer cannot accept responsibility for damage caused when the appliance is not used according to the instructions, or for uses other than those for which it was intended.
WARNING:
- Fully assemble the mister before operating.
- Use and store in a dry location.
- Do not allow the machine to be used as a toy. Close attention is necessary when used by or near children.
- Do not use a charger with a damaged cord or plug. If the appliance or charger is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, contact an authorized service center for service.
- Do not pull or carry the charger by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners.
- Keep the cord away from heated surfaces.
- Do not unplug the charger by pulling on the cord. To unplug the charger, grasp the plug, not the cord.
- Do not handle the charger, including the charger plug and terminals, with wet hands.
- Do not put any object into openings.
- Do not use with any opening blocked. Keep free of dust, lint, hair, and anything that may reduce air flow.
- To ensure disinfection, follow the chemical manufacturer’s recommendation of dwell time (how long the disinfectant sits on a surface) before removal. Dispose of wipe down towel properly or allow the disinfectant to air dry in place.
- Do not charge the unit outdoors.
- Only charge in temperatures between 32° – 113°F (0° – 45°C).
- Do not open, crush, expose to heat above 212°F (100°C), or incinerate the battery even if it is severely damaged.
- Use the battery only with the charger supplied.
- The battery and charger have no serviceable parts and cannot be repaired. Replace only with battery and/or charger part numbers shown in this manual.
SPECIFICATIONS

BOX CONTENTS
Upon initial receipt of the unit, open the box and ensure all parts are included as shown below:



OPERATING INSTRUCTIONS
Initial Assembly
- Remove all contents from the box and ensure all components are present per the BOX CONTENTS section of this manual.
- Firmly attach one end of the hose to the wand assembly and the other end to the machine, ensuring the hose is fully inserted (Figure 1 on page 13).
- Attach the shoulder strap to the unit. The mister can be used with the carrying handle or the shoulder strap (Figure 2 on page 13).
Battery Charging
- Remove the battery and battery charger from the individual boxes.
- Plug the charger AC cable into a 115V wall socket and insert the battery into the charger. The battery was designed to fit into the charger only one way to ensure alignment of the charging ports.
- If the battery needs charging, the light on the charger will turn red. When charging is complete, the red light will turn green. A flashing green light indicates the charger is in stand-by mode.
Battery Installation
It is important NOT to install a battery into a unit that is turned ON. Verify the switch is in the OFF position prior to inserting the battery.
- Once the battery is fully charged, insert the battery in the port located underneath the main unit (Figure 3 on page 14).
- Insert the battery into the port and push until tabs engage. The battery will only insert into port one way.
- To remove the battery, simultaneously depress the tabs on the side of the battery and pull out (Figure 4 on page 14).
- Charge as required.
Do NOT turn the unit ON without verifying there is fluid in the machine. Running the system dry will damage the pump.
Battery Charger Label Definitions

- Lights flash red and green – bad battery.
- Lights are solid red – battery charging.
- Lights flash green – standby mode. Charger plugged in and waiting for battery to be inserted.
- Lights are solid green – battery fully charged.
- Lights flash red – battery too hot to charge. Will begin charging once the battery cools.
Operation
Prior to filling the tank, remove the battery from the unit and place it away from a wet area.
- Remove the cap from the tank.
- Pour the recommended amount of disinfectant into the 1⁄2 gallon tank and fill about 1⁄4 of the way with clean water. Replace the cap and gently shake the contents to mix the disinfectant with water. Remove cap and fill to full (F) line. Note that the solution level can be viewed through the solution level window on either side of the unit.
- Ensure the exterior of the unit is dry before adding the battery.
- Install the battery as outlined under the battery installation section located on page 8.
- Turn the switch to the ON position. You will hear the pump come on to build spraying pressure. Pull the trigger on the wand until a uniform spray is discharged from the end of the wand, and to assist in the self-priming feature.
- The pump will come on each time the trigger is pulled and will run shortly after release to keep pressure on the system. This will repeat during use.
When the product is brand new and/or has not been used for an extended period, it could take up to 30 seconds for fluid to reach the end of the wand. Continue pulling the trigger at startup until a strong flow of mist is observed exiting the wand. - To apply, use a natural up and down or side-to-side motion, ensuring complete coverage by overlapping.
- Over a period of approximately 5 minutes of non-use with the unit ON, pressure may drop enough to “bump” the pump back on for a split second. This is to serve as a reminder that the unit is still ON and should be turned off if use is not intended to keep the battery from draining.
- Allow disinfectant to remain on the surface for the required amount of time based on the manufacturer’s recommendations. Wipe with a clean, dry rag if required, following disinfection.
After Use
- Upon completion of disinfection, empty the contents of the tank into an approved storage container.
- Add 1⁄4 gallon (half full) of clean water to the tank and replace the cap.
- Turn the unit ON, pull the spray trigger, and allow clean water to flush through the system, making sure to follow proper disposal of the water being flushed through the system, as there will be residual chemicals found in the spray (Follow the chemical manufacturer’s recommendation for disposal).
- Turn the unit OFF, pull the spray trigger again to relieve back pressure on the unit.
- Remove battery.
- Empty the contents of the tank and store it dry.
Customer Support
If your system fails to function properly and is not addressed below, contact customer support at 1-800-880-2913. User/freight damage will not be covered.
Troubleshooting

Occasionally, air may enter the system and cause a vacuum lock. This is indicated by a greatly reduced flow of liquid out of the end of the wand. Follow the steps below to correct.
- Turn the machine OFF.
- Pull the wand trigger to remove all pressure from the system.
- Pull the black plastic towards the wand while pulling the coiled hose out of the fitting.

- Point the free end of the hose into the approved container.
- Turn the unit ON until the solution flows freely out of the end of the hose.
- Turn the unit OFF.
- Replace the coiled hose in the wand by simply pushing the free end of the hose back into the fitting until fully seated. It is not necessary to pull the black plastic back as the hose will self-lock when fully inserted.
ASSEMBLY AND MAINTENANCE
Assembly Instructions

Push the hose FULLY into the fitting. Once fitting bottoms out, tug on tubing to ensure a snug fit.

Battery Installation

Spray Tip Replacement
The spray tip is made of plastic and will therefore require replacement over time. Use only the replacement tip listed in the parts section of this manual.

Key Features

Schematics

PARTS LIST

For more manuals by Powr-Flite, visit ManualsLibraryy
Powr-Flite PP200-Q02-U Battery Powered Mister-FAQs
What is the Powr-Flite PP200-Q02-U Battery Powered Mister used for?
The Powr-Flite PP200-Q02-U Battery Powered Mister is designed for efficient disinfecting and sanitizing of indoor and outdoor surfaces. It evenly applies cleaning solutions to hard surfaces in schools, offices, healthcare facilities, and commercial spaces.
What types of equipment does Powr-Flite manufacture?
Powr-Flite produces commercial cleaning equipment such as backpack vacuums, carpet extractors, auto scrubbers, industrial sweepers, hard floor machines, and specialty sanitizing tools like battery-powered misters.
Is Powr-Flite a reliable brand?
Yes, Powr-Flite is well known in the commercial cleaning industry for durable, high-performance machines designed for professional use. The brand focuses on productivity, reliability, and cost-effective operation.
What types of cleaning solutions can be used in the mister?
The unit is compatible with most water-based disinfectants and sanitizers. Avoid flammable, highly corrosive, or thick chemicals unless approved by the manufacturer.
Can the PP200-Q02-U be used in residential settings?
Yes, although designed for commercial use, it can also be used in large homes, garages, or workshops for efficient disinfecting.
What factors affect cleaning performance?
Effective cleaning depends on five key elements: chemical solution, contact time, temperature, mechanical action, and proper procedure. Balancing these factors ensures better sanitizing results.
Who owns Powr-Flite?
Powr-Flite operates under Tacony Corporation, a company specializing in floor care and commercial cleaning equipment.
Where are Powr-Flite products manufactured?
Powr-Flite’s primary manufacturing and distribution facility is located in Fort Worth, Texas, USA.