Whirlpool Magicool Air Conditioner
Identification of parts
Display introduction
Emergency button
Remote controller
- ON/OFF BUTTON: Off when pressing this button
- MODE BUTTON: Press this button to select the operation mode.
- FAN BUTTON: Used to select the fan speed in sequence: auto, high, medium, or low.
- ROOM TEMPERATURE
- SETTING BUTTONS: Used to adjust the room temperature and the timer, as well as real time.
- SENSE BUTTON: Used to enter fuzzy logic operation directly, regardless of whether the unit is on or off.
- SWING BUTTON: Used to stop or start vertical adjustment of the louver swinging and set the desired up/down airflow direction.
- SLEEP BUTTON: Used to set or cancel Sleep Mode operation.
- AROUND U BUTTON: Used to set or cancel AROUND U Mode operation.
- POWER SAVER BUTTON: Used to enter or quit POWER SAVER mode
- TIMER OFF BUTTON: Used to cancel the timer operation.
- TIMER ON/CLOCK BUTTON: Used to set timer operation and clock.
- TURBO BUTTON: Used to start or stop the fast cooling.
- DIM BUTTON: When you press this button, all the displays of the indoor unit will be switched off. Press any button to resume display.
Indication symbols on LCD:
Cooling indicator
Auto fan speed
6th sense indicator
Signal transmit
Dry indicator
Fan only indicator
Heating indicator
High fan speed
Medium fan speed
Low fan speed
Sleep indicator
Around U
Turbo indicator
Display set timer /Display current time
Display the set temperature
Power saver indicator
Remote controller
- How to Insert the Batteries: Remove the battery cover according to the arrow direction. Insert the new batteries, making sure that the (+) and (-) of the battery are matched correctly.
- Storage and Tips for Using the Remote Controller
How to Use
To operate the room air conditioner, aim the remote controller at the signal receiver. The remote controller will operate the air conditioner at a distance of up to 7m when pointing at the signal receptor of the indoor unit.
Operating Instructions
Heating mode is NOT available for a cooling-only air conditioner. Cool mode: This mode is used to control cooling in normal temperatures. The range of 18~32 °C, fan speed settings can be varied. To change the fan speed setting in this mode, press the fan speed button to select any of the 3 fan speeds from High/Medium/Low. The cool mode indicator, along with temperature, is displayed on the RC. Dry mode: This mode is suitable for Humid conditions, where the moisture content is the main discomfort. The tan speed is set too low to facilitate the reduction of the humidity level. Temperature can be varied according to need, and the dry mode indicator is displayed on the RC.
At “FAN ONLY” mode, only “High”, “Medium”, and “Low” are available. At “DRY” mode, the Fan speed is set at “Low” automatically, “FAN” button is Ineffective in this case.
Fan mode: When you do not need to lower the room temperature, you can still use the air conditioner as a simple fan. Fan speed can be selected easily from the High/Medium/Low preset settings.
Airflow direction control
Vertical airflow is automatically adjusted to a certain angle under the operation mode after turning on the unit. The direction of airflow can also be adjusted to your preference requirement by pressing the SWING button of the remote controller.
6th sense mode
Press the 6TBSENSE button, the unit enters 6th sense mode(fuzzy logic operation) directly, regardless of whether the unit is on or off. In this mode, temperature and fan speed are automatically set based on the actual room temperature.
CLOCK setting
How to set the time: Press the Timer On/Clock button for 3 seconds to activate the clock
setting. Then, for setting the minutes, press the Up and Down buttons, and for setting hours, continuously hold the Up or Down buttons for 3 seconds. On setting, press the Timer On/Clock button for 3 seconds to set the real time.
Around the U button
In Around U mode, the air conditioner operates based on the temperature near the
remote rather than that around the machine. A temperature sensor fitted in the remote
helps achieve this, maximizing cooling around the remote. Operation: Used to start or stop the air around the U mode. When you press the Around U button, the sensor in the remote gets activated. This means the temperature keeps dropping until the area around the remote reaches the set temperature.
TIMMER MODE
This mode allows you to switch the air conditioner on/off after a certain amount of time that has been set.
How to set the timer on
Timmer on button can be used to set the timer programming as wished in order to switch on the appliance at your desired time.
- Press the timer ON button; the ON button flashes on the LCD.
Press the timer ON button to increase or decrease the time setting by 1 minute.
Note: If you don’t set the time within 10 seconds after you press the TIMER ON button, the remote controller will exit the TIMER ON mode automatically
SLEEP mode
SLEEP mode can be set in COOLING, HEATING, or DRYING operation mode.
This function gives you a more comfortable environment for sleep.
In SLEEP mode,
- The appliance will stop operating automatically after operating for 8 hours.
- Fan speed is automatically set at low speed.
- The set temperature will rise by 1 °C if the appliance operates continuously in mode for 2 hours, then remains steady.
TURBO mode
- Turbo mode is used to reduce the temperature of your room at the highest possible rate, by operating at the highest fan speed and changing the Set the temperature to 18 °C.
- In TURBO mode, you can set the airflow direction or timer. If you want to escape from TURBO mode, press TURBO, MODE, FAN, ON/OFF, SLEEP, or the TEMPERATURE SETTING button, and the display will return to the original mode.
Functions available in different modes
Maintenance
Front panel maintenance
- Cut off the power supply.
- Hold position A and pull outward to remove the front panel.
- Wipe with a soft and dry cloth.
- Never use a volatile substance such as gasoline or polishing powder to clean the appliance.
- Never sprinkle water onto the indoor unit.
- Reinstall and shut the front panel.
Air filter maintenance
- Switch off the appliances and remove the air filter.
- Clean and reinstall the front panel.
- Clean the front panel again.
Protection
Operating condition
The protective device may trip and stop the appliance in the cases listed below.
Noise pollution
- Install the air conditioner in a place that can bear its weight and operate
more quietly. - Install the outdoor unit at a place where the air discharged and the operational noise would not annoy your neighbors.
- Do not place any obstacles in front of the air outlet of the outdoor unit lest it increase the noise level.
Troubleshooting
Troubleshooting chart
Installation instruction
Select the installation location.
Indoor unit installation
- Installing the mounting plate
- Drill a hole for piping.g
- Indoor unit piping installation
Piping Joints Thermal Insulation:
Piping thermal insulation
Piping Connection:
4. Connecting the Cable
Cable Specifications
FOR MORE MANUALS BY WHIRLPOOL, VISIT MANUALSLIBRARYY