IMPORTANT NOTES

  1. For indoor use only.
  2. Operate between 32 ˚F (0 ˚C) and 104 ˚F (40 ˚C).
  3. Use to control one paddle-type ceiling fan.
  4. Use the ceiling fan’s pull chain to set its speed to the highest setting.
  5. Do not use to control fans that have an integrated fan speed control other than a pull chain (i.e., fans that have a remote control or Wi-Fi), unless the integrated control is removed from the ceiling fan.
  6. Do not connect to any other motor-operated appliance or to any lighting load type.
  7. Do not use it to control lighting loads on a fan.
  8. Not compatible with HomeWorks Sunnata companion dimmers or switches.

Help

  • Videos
  • – Frequently Asked Questions
  • Call us: U.S.A.|Canada|Caribbean 1.844.LUTRON1 (588.7661) (24/7)
  • Mexico: +1.888.235.2910
  • Others: +1.610.282.3800

Installing your fan control

Set the fan speed

Set the fan to the highest speed using the pull chain.

Turn the power off at the circuit breaker!

Lutron HRST-ANF HomeWorks Fan Control-1

Remove the existing switch from the wall.

  • Remove the wallplate from the switch.
  • Pull the switch away from the wall.

Lutron HRST-ANF HomeWorks Fan Control-2

Place a tag on the fan wire (if unsure, pick one). If the fan does not work, turn the power off and swap wires.

Lutron HRST-ANF HomeWorks Fan Control-3

Disconnect all three wires from the switch

Connect the fan control

Lutron HRST-ANF HomeWorks Fan Control-4

  1. Connect the bare copper (or green) “ground” wire from the wallbox to the green wire on the fan control using a wire connector.
  2. Wrap the line/hot wire around the screw terminal and tighten securely. Torque reference: 5 in-lb (0.55 N•m).
  3. Connect the neutral wire from the wallbox to the white wire on the fan control using a wire connector.
  4. Connect the fan/tagged wire from the wallbox to the yellow wire on the fan control using a wire connector.
  5. Mount the fan control on the wall.
  6. Turn the power back on.

Set-Up with system

  • For use in a HomeWorks system, please refer to www.lutron.com/HWsupport
  • For reliable performance in a system, Clear Connect-Type X devices must be located within 75 ft (22.8 m) of a centrally located HomeWorks wireless processor/gateway. Each Sunnata Fan Control should have at least two other non-battery-powered Clear Connect-Type X devices within 25 ft (7.6 m).
  • Examples of Clear Connect-Type X devices include the HomeWorks wireless
    processor/gateway, Sunnata dimmers, Sunnata switches, and Sunnata keypads.
    Companion dimmers/switches are not Clear Connect-Type X devices, and are not required to be within a specific range of a HomeWorks wireless processor/gateway

Operation

Lutron HRST-ANF HomeWorks Fan Control-5

ON:

  • Default – Fan goes to the previous fan speed
  • See Sunnata Advanced Feature Mode Application Note #734 (P/N 048734)
    to change this behavior • Anytime – Double-tap to maximum speed.

Adjust: (Light Bar)

  • Touch the light bar to set the fan to one of the 4 speeds (High, MediumHigh, Medium, and Low).

OFF:

  • Fan turns off

Troubleshooting

Lutron HRST-ANF HomeWorks Fan Control-6

CAUTION
Use only with permanently installed ceiling fans. To avoid overheating and possible damage to other equipment, do not use it to control receptacles, motor-driven appliances, or transformer-supplied appliances.

Codes
Install in accordance with all national and local electrical codes.

Grounding
When no “grounding means” exist in the wallbox, the National Electrical Code (NEC®) allows a control to be installed as a replacement if 1) a nonmetallic, noncombustible
faceplate is used with nonmetallic attachment screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI). When installing a control according to these methods, cap or remove the green wire before screwing the control into the wallbox.

FOR MORE MANUALS BY LUTRON, VISIT MANUALSLIBRARYY

Lutron HRST-ANF HomeWorks Fan Control-FAQs

Q1. What is Lutron HomeWorks?

Lutron HomeWorks is a premium automation system that integrates lighting, shading, fan control, HVAC, and audio-visual systems for seamless smart home management.

Q2. How does the Lutron HRST-ANF fan control work?

It regulates the electrical current sent to the fan motor, allowing smooth adjustment of fan speeds without noise or flicker.

Q3. How do I reset a Lutron fan switch?

Turn off power at the circuit breaker for a few seconds, restore power, and press the control button until the indicator light flashes.

Q4. What should I do if my fan switch is not working?

Check the wiring and connections, test with a multimeter, and if faulty, replace the switch. Also ensure the fan motor is not defective.

Q5. Can I use a dimmer to control a fan?

No. Standard dimmer switches are not compatible with fan motors. Use only a dedicated Lutron fan control for safe and reliable operation.

Q6. Does Lutron require Wi-Fi to work?

No. Lutron devices communicate using Clear Connect wireless technology, which works independently of Wi-Fi or internet.

Q7. What are the main disadvantages of Lutron systems?

They can be more expensive than basic controls and often require centralized wiring for installation, which may add complexity.

Q8. Can I install a Lutron fan control myself?

Yes, if you’re comfortable with electrical wiring. However, professional installation is recommended for HomeWorks systems to ensure safety and performance.