
Sharper Image SI637 IONIC BREEZE QUADRA Air Purifier

IMPORTANT SAFETY INFORMATION
WARNING: To reduce the risk of fire, electric shock, or injury when using any electrical appliance, basic precautions should always be followed, including:
- This appliance operates at 1110VAC and 60Hz only.
- Connect to a properly grounded outlet only.
- Use indoors only.
- Unplug from the outlet when not in use and before servicing.
- Do not use the appliance as a toy. Close attention is necessary when operating the appliance near children.
- Use only as described in this user manual.
- Do not use if the cord or plug appears to be damaged. If the appliance is not working properly, or has been dropped, damaged, left outdoors, or dropped into water, return it to a service center or to the original place of purchase.
- Do not pull, lift, or carry by the power cord. Do not use the cord as a handle, close a door on the cord, or pull the cord around or against sharp edges or corners.
- Keep the cord away from heated surfaces.
READ AND SAVE THESE INSTRUCTIONS
Important Information – Please Read
The collection grid has many edges and areas that can trap water. It must be completely dry before being re-inserted, or the unit could be damaged. If water is used to clean the grid, please allow at least 24 hours for the collection grid to dry.
This unit should not be located near a fire replace, whether or not the fire replace is actually in operation. Dust and soot from the chimney could be rapidly drawn through the Ionic Breeze and deposited on or around the unit.
In rooms where candles or oil lamps are frequently burned, the smoke from these products will tend to stick to the outside of the Ionic Breeze. Avoid placing the Ionic Breeze in a location where it will be subjected to smoke from oil lamps or candles. In any area where this product will be subjected to heavy pollution or smoke, it will be necessary to clean the collection grid more frequently.
If the unit begins to arc or make a “static” type of sound, turn the unit off, then slide the collection grid out and invert the unit slowly, several times. Replace the grid.
Frequently Asked Questions
About the Ionic Breeze® QuadraTM
How often is cleaning required?
About every two weeks or anytime the Ionic Breeze makes an audible sound or the CLEANING INDICATOR flashes.
How should it be cleaned?
Wipe the removable collection grid with a damp cloth, paper towel, or wash it in your kitchen sink. The collection grid must be allowed to dry completely before returning it to the main housing.
What is the clean, fresh scent I smell?
This scent is ozone (O3), a combination of three oxygen atoms. (The U.S. government has set safe standards for ozone, and the Ionic Breeze complies with those standards.)
Which power setting should I use?
If the odor of ozone is strong (for instance, in a smaller room), you may prefer to have the power setting on medium or low.
Please read this product instruction manual for important safety information and operating instructions.
Set-Up and Operation
- Place the Ionic Breeze on a level surface, at least twelve inches from the wall.
Plug into a grounded 110V outlet (read warnings for details).
- Set-Up and Operation Activate the unit by pressing the CONTROL BUTTON located on top of the unit.
The unit will clean, ionize, and circulate the air with periodic bursts, ramping the air flow up and down in a preprogrammed cycle.
- Select the desired power level by pressing the CONTROL BUTTON to rotate through the HI, MED, LO, or OFF settings. The selected level is indicated by the green LEDs.

- This unit must be cleaned at least once every two weeks. If cleaning is neglected, the unit will shut down. (Indicated by a red LED.)
Normal operation can only be resumed after the grid has been cleaned.
Cleaning the Collection Grid
Cleaning of the grid is required every one or two weeks.
- Unplug the unit before cleaning.
Remove the collection grid by pulling it from the top of the unit.
- Use a dry or slightly damp towel or sponge to quickly wipe the dust from each of the three collection bars.
Invert the entire unit for three seconds before replacing the collection grid.
Thorough Cleaning
If the unit makes noise during operation, a thorough cleaning of the grid and ionizing wires may be required.
- Remove the collection grid by pulling it from the top of the unit.
Wash the grid with warm, soapy water, rinse, and allow to dry for 24 hours before returning to the unit.
- Invert the main housing several times before replacing the collection grid.
This action will remove any accumulated particles from the ionizing wires.
Additional Information
The exterior of the unit can be safely cleaned using a soft cloth or sponge and a solution of one part household bleach to five parts water.
Allow the surface to dry for 24 hours before plugging it back into an outlet.
The Ionic Breeze® complies with U.S. safety standards for low ozone emission (less than 50 parts per billion). We recommend that individuals with a history of respiratory disease consult with their doctor about possible heightened sensitivity to very low ozone.
Statement of FCC/DHHS compliance
Model: SI637
WARNING:
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE:
This product complies with DHHS Rule 21 subchapter J as of the date of manufacture. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for assistance.
FULL FIVE-YEAR WARRANTY
What Is Covered
This warranty covers any defects in materials or workmanship, with the exceptions stated below.
How Long Does Coverage Last
This warranty runs for five years from the date of original purchase.
What Is Not Covered
This warranty does not cover damage caused by misuse or use other than as intended and described in the instruction manual, or damage caused by failure to properly clean and maintain this product.
What The Sharper Image Will Do
The Sharper Image will repair any defects in materials or workmanship. Or, The Sharper Image will have the option to either replace this product with a fully warranted, reconditioned unit or refund the purchase price of the product.
How to Obtain Service
Return the product and receipt, along with a brief explanation of the problem, to:
T.S.I. – Returns Department
2901-A West 60th Street
Little Rock, AR 72209
If You Have Questions
Please feel free to contact our customer service representatives at 1-800-344-5555 or by email at [email protected].
This warranty gives you specific rights, and you may have other legal rights that vary from state to state.
Copyright 2001, 2002, 2003
Sharper Image Corporation
For more manuals by Sharper Image, visit ManualsLibraryy
Sharper Image SI637 IONIC BREEZE QUADRA Air Purifier- FAQs
Q1. How does the Ionic Breeze Quadra work?
It uses ionization technology to release negatively charged ions that attach to airborne particles, causing them to drop from the air.
Q2. Does the Ionic Breeze require filters?
No. This purifier does not use traditional filters, making it low-maintenance compared to filter-based purifiers.
Q3. How do I clean the Ionic Breeze Quadra?
Turn off the unit, remove the collection blades, and wipe them gently with a damp cloth. Let them dry completely before reinstalling.
Q4. Should I keep doors and windows closed while using it?
Yes, the purifier works best in a closed room where outside air cannot dilute its cleaning efficiency.
Q5. How do I know if my air purifier is cleaning the air?
Check for visible dust on the collection blades and notice reduced dust or allergens in the room after consistent use.
Q6. Is it safe to sleep with the Ionic Breeze on?
Yes, you can keep it running overnight. Just ensure it is placed away from your bed for comfortable airflow.
Q7. Where should I place the Ionic Breeze Quadra?
For maximum performance, position it in the center of the room or near a main airflow path, away from walls and corners.
Q8. Are there any side effects of ionic air purifiers?
Some models may produce small amounts of ozone, which can cause throat irritation in sensitive users. Use in well-ventilated spaces if needed.








