Rheem Criterion II Plus 2 Gas Furnace User Manual

Rheem logo

Rheem Criterion II Plus 2 Gas Furnace

Rheem Criterion II Plus 2 Gas Furnace User Manual-prod

Rheem Criterion II Plus 2 Gas Furnace User Manual-1

STANDARD EQUIPMENT

Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multispeed blower motor.

Furnaces are equipped with a cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; onboard twinning; fused transformer (secondary), 3rd speed option for continuous fan; common heat/cool terminal.

All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory-approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor.

PHYSICAL DATA AND SPECIFICATIONS

MODEL NUMBERS RGLH- SERIES05EAUER

05NAUER

07EAUER

07NAUER

07EAMGR

07NAMGR

10EAMER

10NAMER

10EBRJR

10NBRJR

12EARJR

12NARJR

15EARJR

15NARJR

Input–BTU/Hr [kW] ➁50,000 [15]75,000 [22]75,000 [22]100,000 [29.3]100,000 [29.3]125,000 [36.6]150,000 [44]
Heating Capacity BTU/Hr [kW] ➀41,000 [12]60,000 [18]60,500 [18]80,000 [23]81,000 [24]99,000 [29]120,000 [35]
High Altitude Input [kW]45,000 [13]67,500 [19.8]67,500 [19.8]90,000 [26.4]90,000 [26.4]112,500 [33]135,000 [39.6]
High Altitude Output Capacity [kW]36,500 [10.7]53,500 [15.7]54,000 [15.8]72,000 [21.1]72,500 [21.2]89,000 [26.1]107,500 [31.5]
Heat Ext. Static Pressure [kPa].10 [.025].12 [.029].12 [.029].15 [.037].15 [.037].20 [.05].20 [.05]
 

Blower (D x W) [mm]

 

11 x 6

[279 x 152]

 

11 x 6

[279 x 152]

 

11 x 7

[279 x 178]

11 x 6 = 10*AU

[279 x 152]

11 x 7 = 10*AM

[279 x 178

 

11 x 10

[279 x 254]

 

11 x 10

[279 x 254]

 

11 x 10

[279 x 254]

Motor H.P. [W]–Speeds [W]– PSC Type1/2-4-PSC

[373]

1/2-4-PSC

[373]

3/4-4-PSC

[559]

1/2-4-PSC

[373]

3/4-4-PSC

[559]

3/4-4-PSC

[559]

3/4-4-PSC

[559]

Motor Full Load Amps6.87.19.57.19.59.59.5
Heating SpeedMED-LOWMED-HIGHMED-LOWMED-HIGHMED-LOWMED-LOWMED-LOW
Cooling SpeedHIGHHIGHMED-HIGHHIGHMED-HIGHMED-HIGHMED-HIGH
Cooling CFM @ .5″ [kPa] E.S.P. (Nominal) [L/s]1200

[566]

1200

[566]

1600

[755]

1200

[566]

2000

[944]

2000

[944]

2000

[944]

Rated E.S.P. (In. W.C.) [kPa].50 [.12].50 [.12].50 [.12].50 [.12].50 [.12].50 [.12].50 [.12]
 

Temperature Rise Range °F [°C]

 

25-55

[13.9-30.6]

 

40-70

[22.2-38.9]

 

25-55

[13.9-30.6]

55-85 = 10*AU

[30.6-47.2]

45-75 = 10*AM

[25-41.7]

 

40-70

[22.2-38.9]

 

40-70

[22.2-38.9]

 

50-80

[27.8-44.4]

Max. Outlet Air Temp. °F [°C]155

[68.3]

165

[73.9]

155

[68.3]

190

[87.8]

190

[87.8]

180

[82.2]

190

[87.8]

Standard Filter [mm](1) 14 x 20

[356 x 508]

(2) 12 x 20

[305 x 508]

(2) 12 x 20

[305 x 508]

(2) 12 x 20

[305 x 508]

(2) 14 x 20

[356 x 508]

(2) 14 x 20

[356 x 508]

(2) 14 x 20

[356 x 508]

Approx. Shipping Weight (Lbs.) [kg]85

[38.6]

105

[47.6]

105

[47.6]

115

[52.2]

120

[54.4]

140

[63.5]

150

[68.0]

AFUE–Electric Ignition Models ➀82.2%80.5%81.1%80.2%80%80%80%
California Seasonal Efficiency– Electric Ignition Nox Models75.9/76.274.4/74.975.1/75.575.2/75.274.7/74.775.2/75.376.0/75.9

MODEL IDENTIFICATION—DOWNFLOW MODELS

Rheem Criterion II Plus 2 Gas Furnace User Manual-2

DOWNFLOW DIMENSIONS

Rheem Criterion II Plus 2 Gas Furnace User Manual-3Rheem Criterion II Plus 2 Gas Furnace User Manual-4

TABLE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]

MODEL RGLH- SERIES 

A

 

B

 

C

 

D

 

E

REDUCED CLEARANCES (IN.) [mm]
LEFT SIDERIGHT SIDEBACKTOPFRONTVENTSHIP. WGTS. (LBS.) [kg]
0514  [356]1227/32 [326]103/8 [264]131/8 [333]04 ➁01 [25]3 [76]6 [152] ➂85 [38.6]
07171/2 [445]1611/32 [415]121/8 [308]165/8 [422]03 ➁01 [25]3 [76]6 [152] ➂105 [47.6]
10 (A)171/2 [445]1611/32 [415]121/8 [308]165/8 [422]03 ➁01 [25]3 [76]6 [152] ➂115 [52.2]
10 (B)21  [533]1927/32 [504]137/8 [352]201/8 [511]0001 [25]3 [76]6 [152] ➂120 [54.4]
12241/2 [622]2311/32 [593]155/8 [397]235/8 [600]0001 [25]3 [76]6 [152] ➂140 [63.5]
15241/2 [622]2311/32 [593]155/8 [397]235/8 [600]0001 [25]3 [76]6 [152] ➂150 [68]

BLOWER PERFORMANCE DATA—DOWNFLOW MODELS

MODEL NUMBER RGLH- SERIESBLOWER SIZE

[mm]

MOTOR H.P.

[W]

 

BLOWER SPEED

CFM [L/s] AIR DELIVERY

EXTERNAL STATIC PRESSURE INCHES [kPa] WATER COLUMN

.1 [.02].2 [.05].3 [.07].4 [.10].5 [.12].6 [.15].7 [.17]
05MAUER

05EAUE

05NAUER

 

11 x 6

[279 x 152]

 

1/2 [373]

LOW MED-LO MED-HI HIGH735 [347]

1025 [484]

1185 [559]

1345 [635]

715 [337]

1015 [479]

1165 [550]

1330 [628]

690 [326]

995 [470]

1150 [543]

1310 [618]

660 [311]

975 [460]

1130 [533]

1295 [611]

635 [300]

955 [451]

1100 [519]

1265 [597]

605

930

1075

1235

[286]

[439]

[507]

[583]

575 [271]

905 [427]

1040 [491]

1205 [569]

07MAUER

07EAUE

07EAUER

 

11 x 6

[279 x 152]

 

1/2 [373]

LOW MED-LO MED-HI HIGH835 [394]

990 [467]

1140 [538]

1300 [614]

820 [387]

975 [460]

1125 [531]

1290 [609]

800 [378]

955 [451]

1105 [522]

1265 [597]

775 [366]

935 [441]

1080 [510]

1245 [588]

750 [354]

905 [427]

1050 [496]

1215 [573]

720

875

1020

1180

[340]

[413]

[481]

[557]

685 [323]

835 [394]

980 [463]

1140 [538]

07MAMGR

07EAMG

07NAMGR

 

11 x 7

[279 x 178]

 

3/4 [559]

LOW MED-LO MED-HI HIGH1210 [571]

1580 [746]

1915 [904]

1205 [569]

1560 [736]

1880 [887]

2050 [967]

1195 [564]

1550 [732]

1825 [861]

1995 [942]

1180 [557]

1530 [722]

1790 [845]

1940 [916]

1165 [550]

1495 [706]

1740 [821]

1885 [890]

1155

1465

1675

1835

[545]

[691]

[791]

[866]

1130 [533]

1430 [675]

1600 [755]

1770 [835]

***LOW935 [441]*910 [429]*885 [418]*855 [404]*825 [389]*785[370]*760 [359]*
10EAME*

10NAMER

11 x 7

[279 x 178]

1/2 [373]MED-LO MED-HI HIGH1070 [505]

1240 [585]

1420 [670]

1055 [498]

1210 [571]

1395 [658]

1040 [491]

1190 [562]

1370 [647]

1010 [477]

1165 [550]

1340 [632]

980 [463]

1135 [536]

1305 [616]

945

1095

1265

[446]

[517]

[597]

905 [427]

1055 [498]

1220 [576]

 

10EBRJR

10NBRJR

 

11 x 10

[279 x 254]

 

3/4 [559]

LOW MED-LO MED-HI HIGH1330 [628]

1690 [798]

1295 [611]

1670 [788]

2085 [984]

2410 [1137]

1285 [606]

1655 [781]

2055 [970]

2355 [1111]

1245 [588]

1615 [762]

2005 [946]

2305 [1088]

1225 [578]

1585 [748]

1970 [930]

2240 [1057]

1205 [569]

1565 [739]

1945 [918]

2165 [1022]

1160 [547]

1525 [720]

1880 [887]

2100 [991]

 

12EARJR

12NARJR

 

11 x 10

[279 x 254]

 

3/4 [559]

LOW MED-LO MED-HI HIGH1330 [628]

1295 [611]

1690 [798]

2090 [986]

2395 [1130]

1280 [604]

1660 [783]

2035 [960]

2335 [1102]

1240 [585]

1635 [772]

1985 [937]

2260 [1067]

1215 [573]

1580 [746]

1930 [911]

2185 [1031]

1210

1535

1850

2080

[571]

[724]

[873]

[982]

1175 [555]

1480 [698]

1785 [842]

1965 [927]

15MARJR

15EARJR

15NARJR

 

11 x 10

[279 x 254]

 

3/4 [559]

LOW MED-LO MED-HI HIGH1300 [614]

1675 [791]

2105 [993]

1280 [604]

1650 [779]

2075 [979]

2340 [1104]

1230 [580]

1620 [765]

2035 [960]

2290 [1081]

1205 [569]

1570 [741]

1990 [939]

2215 [1045]

1170 [552]

1545 [729]

1955 [923]

2145 [1012]

1115

1485

1900

2080

[526]

[701]

[897]

[982]

1030 [486]

1425 [673]

1815 [857]

1995 [942]

ACCESSORIES—DOWNFLOW

DOWNFLOW WARNING: Unit design is certified for installation on a non-combustible floor. A special factory-supplied combustible floor sub-base is required when installing on a combustible floor. Failure to install the sub-base may result in fire, property damage, and personal injury.

COMBUSTIBLE FLOOR BASE DIMENSIONS

COMBUSTIBLE FLOOR BASEUSE WITH FURNACE SIZESA

IN. [mm]

B

IN. [mm]

C

IN. [mm]

RXGC-B14RGLH-05141/2 [368]131/4 [337]111/4 [286]
RXGC-B17RGLH-07, RGLH-10(-)A18  [457]163/4 [425]143/4 [451]
RXGC-B21RGLH-10(-)B211/2 [546]201/4 [514]181/4 [464]
RXGC-B24RGLH-12, RGLH-1525  [635]233/4 [603]213/4 [552]

PLENUM DATA—“A” COILS

Plenum adapters are required in some instances for use on downflow applications when plenum and furnace sizes do not match.

FURNACE WIDTH IN. [mm]PLENUM WIDTH IN. [mm]PLENUM ADAPTER DOWNFLOWCOIL PLENUM
14  [356]161/4 [413]RXAA-C178RXAL-B16BU
14  [356]201/4 [514]RXAA-C179RXAL-B20BU
171/2 [445]161/4 [413]RXAA-C186RXAL-B16BU
171/2 [445]201/4 [514]RXAA-C180RXAL-B20BU
171/2 [445]215/8 [549]RXAA-C189RXAL-B21BU
171/2 [445]251/4 [641]RXAA-C181RXAL-B25BU
21  [533]221/4 [565]RXAA-C182RXAL-B22BU
21  [533]251/4 [641]RXAA-C183RXAL-B25BU
241/2 [622]251/4 [641]RXAA-C184RXAL-B25BU
241/2 [622]215/8 [549]RXAA-C190RXAL-B21BU

Rheem Criterion II Plus 2 Gas Furnace User Manual-5

RXPF-F01 and F02

FOSSIL FUEL KITS—are for use with Rheem Heat Pumps and Criterion II warm air furnaces. The RXPF-F02 meets TVA requirements.

RXGF-C

FILTER RACK—Downflow top return mount. NOTE: Filter racks are shipped without filters. Filters are available through PROSTOCK™.

OPTION CODE FOR HIGH ALTITUDE: US-277 Canada-298 (Kit packaged with furnace. Requires field installation.)

GENERAL TERMS OF LIMITED WARRANTY

Rheem will furnish a replacement for any part of this product that fails in normal use and service within the applicable period stated, by the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy.

For more manuals by Rheem  visit, ManualsLibraryy

Rheem Criterion II Plus 2 Gas Furnace-FAs

How do I reset my Rheem Criterion II gas furnace?

Turn off the power and locate the reset button near the burner chamber. Press the small button between the two leads. If you hear a click, the reset was successful. Turn the power back on, and the furnace should start working.

What does code 2 mean on a Rheem furnace?

A 2-blink error code indicates an issue with the negative pressure switch circuit, meaning the switch is either not closing or reopening unexpectedly.

Why does my Rheem furnace keep shutting off?

This could be due to a venting issue or insufficient airflow through the burners. If the inducer fan motor isn’t drawing enough air, the rollout switch will trip to prevent overheating, causing the furnace to shut off after a few minutes.

How long should a two-stage furnace run?

A single-stage furnace typically runs in 10- to 15-minute cycles, two or three times per hour. A two-stage furnace runs mostly on a lower setting and operates nearly continuously for more even heating.

What do W1 and W2 mean on a furnace?

W1 controls the first stage of heating, while W2 activates the second stage for additional heating when needed. This helps maintain consistent indoor temperatures efficiently.

Why does my furnace have two filters?

If your HVAC system has multiple return vents, each vent may have its own filter to ensure proper air filtration and prevent dust and debris from entering the system.

Does the thermostat control a two-stage furnace?

Yes, the thermostat regulates a two-stage furnace automatically. It first activates the low setting and will switch to high if additional heat is required.

Why does my furnace turn on and off every two minutes?

Frequent cycling can be caused by dirty filters, blocked ducts, incorrect thermostat settings, or a faulty limit switch. Regular maintenance can help prevent short cycling and improve efficiency.