GE Dehumidifier APER50 50 Pint Portable Dehumidifier
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock, or personal injury.
- Use this appliance only for its intended purpose as described in this Owner’s Manual.
- This dehumidifier must be properly installed and grounded as described in this manual before it is used.
- Never operate this dehumidifier in an area that is likely to accumulate standing water. If this condition develops, for your safety, disconnect the power supply before stepping into the water.
- Never unplug your dehumidifier by pulling on the power cord. Always grip the plug firmly and pull straight out from the receptacle.
- Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
- If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
- If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person in order to avoid a hazard.
- The appliance shall be installed in accordance with national wiring regulations.
- Turn the dehumidifier OFF and unplug it before cleaning.
- GE Appliances does not support any servicing of the dehumidifier. We strongly recommend that you do not attempt to service the dehumidifier yourself.
- For your safety, do not store or use combustible materials, gasoline, or other flammable vapors or liquids in the vicinity of this or any other appliance.
- All dehumidifiers contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
- Do not use outdoors.
- This dehumidifier is intended for indoor residential applications only. This dehumidifier should not be used for commercial or industrial applications.
- These R410A Dehumidifier Systems require contractors and technicians to use tools, equipment, and safety standards approved for use with this refrigerant. DO NOT use equipment certified for R22 refrigerant only.
- This appliance can be used by persons with reduced physical, sensory, or mental capabilities or a lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
USE OF EXTENSION CORDS
RISK OF FIRE. It could cause serious injury or death.
- DO NOT use an extension cord with this Dehumidifier.
- DO NOT use surge protectors or multi-outlet adaptors with this Dehumidifier.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug, which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of an electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The dehumidifier should always be plugged into its own individual electrical outlet, which has a voltage rating matching the rating plate.
This provides the best performance and also prevents. overloading house wiring circuits, which could cause a fire hazard from overheated wires.
RECYCLING INFORMATION
For appliance recycling information, please visit www.geappliances.com/recycling.
READ AND SAVE THESE INSTRUCTIONS
OPERATING INSTRUCTIONS
Controls
NOTE: When the bucket is full or removed, the controls cannot be set.
Power Pad
Press to turn the dehumidifier on and off.
Filter Timer
After 250 hours of operation, the Clean the Filter indicator light will glow to remind you to clean the filter. Remove the filter and clean it.
Press to turn off the Clean the Filter light. See the Care and Cleaning section.
Humidity Set Control Pads
The humidity level can be set within a range of 35% RH (Relative Humidity) to 80% RH (Relative Humidity) in 5% increments or at NS for continuous operation. To set the unit for continuous operation, press the — pad until the screen reads NS.
NOTE: If NS (Nonstop) is selected, the dehumidifier will operate continuously at its maximum dehumidification settings if attached to a hose to drain or until the bucket is full.
For drier air, press the — pad and set to a lower percent value (%).
For damper air, press the + pad and set to a higher percent value (%).
When you first use the dehumidifier, set the humidity control to 45% or 50%. Allow at least 24 hours for the dehumidifier to achieve the desired humidity level. If you still have damp air than desired, set the humidity level to a lower setting or select Nonstop for maximum dehumidification.
Display
Shows the set % humidity level while setting, then shows the actual (+/- 5% accuracy) room % humidity level.
Fan Speed Pad
Controls the fan speed.
Press to select either High, Medium, or Low fan speed.
Set the fan control to High for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred, set the fan control to Medium or Low.
Delay Off
While the dehumidifier is in operation, press this pad to set it to automatically turn off in 2 hours or 4 hours.
Pump
Activates the internal pump function. Press for 3 seconds to activate the internal pump for automatic removal of condensate. The internal pump indicator light will remain illuminated for 3 seconds. Press to deactivate the pump.
Other Features
Empty Light
Glows when the bucket is ready to be emptied, or when the bucket is removed or not replaced in the proper position.
Alarm
If the bucket is full or missing for more than 3 minutes, an alarm will sound for about 10 seconds to remind you to empty and replace the bucket.
Auto Shut Off
The Water Level Control Switch shuts off the dehumidifier when the bucket is full, or when the bucket is removed or not replaced in the proper position. NOTE: The Fan will continue to run approximately 3 minutes after the bucket is removed.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off, and the fan will continue to run until the frost disappears.
Power Outage
In the case of a power outage or interruption, the unit will automatically restart, in the settings last used, after the power is restored.
Using the Dehumidifier
When first using the dehumidifier, operate the unit continuously for 24 hours.
How the Dehumidifier Operates
Moist, humid air is drawn over a cold refrigerated dehumidifying coil. Moisture in the air condenses on this coil and drains into a bucket (or through a hose and drain).
Dry, clean air is drawn through the condenser where it is heated and discharged out the top grille into the room.
It is normal for the surrounding air to become slightly warmer as the dehumidifier operates.
Automatic Defrost
When frost builds up on the evaporator coils, the compressor will cycle off, and the fan will continue to run until the frost disappears.
When the coil is defrosted, the compressor or fan will automatically restart, and dehumidifying will resume.
Choosing a Location
A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area.
- Do not use outdoors.
- This dehumidifier is intended for indoor residential applications only. This dehumidifier should not be used for commercial or industrial applications.
- Place the dehumidifier on a smooth, level floor strong enough to support the unit with a full bucket of water.
- Allow at least 18 inches of air space on all sides of the unit for good air circulation.
- Place the dehumidifier in an area where the temperature will not fall below 41°F (5°C) or above 90°F (32°C). The coils can become covered with frost at temperatures below 41°F, which may reduce performance.
- The suggested range of relative humidity is between 30% and 90%.
- Use the dehumidifier in cooking, laundry, bathing, and dishwashing areas that have excessive moisture. NOTE: Place the dehumidifier away from the clothes dryer.
- Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored.
- Use the dehumidifier in a basement to help prevent moisture damage.
- The dehumidifier must be operated in an enclosed area to be most effective.
- Close all doors, windows, and other outside openings to the room.
NOTE: The dehumidifier has rollers to aid placement, but it should only be rolled on smooth, flat surfaces. Do not attempt to roll the dehumidifier on carpet or over objects.
Always make sure the water bucket is locked into place on the dehumidifier.
Removing Collected Water
There are 3 ways to remove collected water:
Use the bucket. When the bucket is removed, the unit will shut off. Empty and replace the bucket.
IMPORTANT: Do not use the hose if using the bucket to collect water. When the hose is connected, water will flow through it onto the floor instead of into the bucket.
NOTES:
- Do not remove the bucket while the dehumidifier is operating or if it has just stopped operating. This might cause some water to drip from the drain pan.
- The bucket must be in place and securely seated for the dehumidifier to operate.
Use a hose. Water can be automatically emptied into a floor drain by attaching a garden water hose (not included).
- Remove the bucket from the front of the unit.
- Open the drain cover on the side of the unit.
- Thread a garden hose (not supplied) onto the nozzle, cut to length, and lead it to the floor drain.
- Replace the bucket in the unit.
NOTE: The bucket must be in place and securely seated for the dehumidifier to operate.
Use the internal pump. Water can be automatically emptied into a remote location by attaching the included pump hose.
- Attach the pump hose to the hose connector by pushing the tube fitting into the connector until it fits into place (should not be able to remove the hose when pulled).
- Position the hose discharge to the desired location.
- Make sure the pump is activated. To activate the pump, press and hold the Pump button for 3 seconds. The Pump indicator light will flash, then remain illuminated once the 3 seconds are complete.
IMPORTANT: The Pump will not begin removing water until the buckets are full. After the pump button has been activated by holding for 3 seconds, the pump will remain on standby. When the bucket is full, the pump will automatically begin removing water and stop when the bucket is emptied. This cycle will continue until the pump button is deactivated.
IMPORTANT: Make sure the condensate hose is properly connected and is not kinked, bent, or cracked, as this may cause water to flow onto the floor. The bucket must also be fully seated for the pump to work properly. Do not operate the machine if the room temperature is 32°F or below.
NOTES:
- Maximum lift height is 16.
- The bucket must be in place and securely seated for the dehumidifier and pump to operate.
Make sure to install the hose (included) before activating the pump.
To Install Hose: Push in the hose and gently pull to make sure it is secure. It should not be able to be removed.
To Release Hose: Hold the grey ring while pulling to remove.
NOTE: DO NOT kink or crimp the hose, as it can block water flow.
Water Level
The dehumidifier will turn off automatically when the bucket is full, or when the bucket is removed or not replaced in the proper position.
The bucket must be replaced in the proper position for the dehumidifier to work. The bucket full light will be on, and the dehumidifier will not run if the bucket is not in the proper position.
Bucket Operation
DO NOT remove the foam piece in the bucket assembly. If the Dehumidifier does not work properly.
When the coil is defrosted, the compressor or fan will automatically restart, and dehumidifying will resume.
Care and Cleaning
Turn off the dehumidifier and remove the plug from the wall outlet before cleaning.
Grille and Case
To clean the case:
Use water and a mild detergent. Do not use bleach or abrasives.
To clean the front grille:
Use a vacuum attachment or brush.
Water Bucket
To clean:
Every few weeks, clean the bucket to prevent the growth of mold, mildew, and bacteria. Partially fill the bucket with clean water and add a little mild detergent. Swish it around in the bucket, empty, and rinse.
NOTE: Do not use a dishwasher to clean the water bucket.
To remove:
Remove the bucket and pour out any water.
To replace:
Set the bucket into the dehumidifier.
NOTE: The bucket must be in place and securely seated for the dehumidifier to operate.
Air Filter
The air filter behind the front grille should be checked and cleaned at least every 250 hours of operation or more often if necessary.
After 250 hours of operation, the Clean the Filter indicator light will glow to remind you to clean the filter. Remove the filter and clean it. Replace the filter and press the Filter Timer pad to turn off the Clean the Filter light.
To remove:
Remove the bucket. Grasp the filter edge and pull it straight down and out.
To clean:
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.
NOTE: DO NOT put the filter in an automatic dishwasher.
CAUTION: Do not operate the dehumidifier without a filter because dirt and lint will clog it and reduce performance.
Bucket Filter
The bucket filter is located inside the bucket near the bottom. The filter should be checked when cleaning the bucket. If the filter has any debris on it, gently remove the filter as described below and rinse with warm water.
Replace the filter in the bucket once it is clean.
TO REMOVE THE FILTER:
- Squeeze both clasp inward to disengage the clasp clips from the water tank cover. Lift the cover upwards to remove.
- Lift the end of the filter upwards to remove the filter.
- Place the large end of the filter above the tabs, press the filter down firmly to spread the tabs. Once the filter is between tabs, press the fire inward to engage the tabs into the fire.
- Replace the water tank cover and handle.
Storage
If the unit is to be stored for an extended period of time, take the following actions before putting away the machine.
- Empty the bucket of all water.
- Clean the water bucket and bucket filter per instructions.
- Allow the water bucket to dry and reinstall.
- Remove the pump hose and store it with the unit.
To Release Hose: Hold the grey ring while pulling the hose to remove.
Troubleshooting Tips
Before you call for service
Save time and money! Review the charts on the following pages first, and you may not need to call for service.
For more Manuals by General Electric, visit ManualsLibraryy