SAFETY RULES

WARNING — READ AND SAVE THESE INSTRUCTIONS BEFORE USING THIS PRODUCT.

The use of electrical products may create hazards that include, but are not limited to injury, fire, electrical shock. Failure to follow these instructions may damage and/ or impair its operation and void the warranty. In case there is any inconsistency or conflict between the English version and any other language version of the content of this material, the English version shall prevail.

When using electrical appliances, basic safety precautions should always be followed:

  • DO NOT touch the dehumidifier or the electrical plug with wet hands.
  • Check the household voltage to ensure it matches the appliance’s specification.
  • Before operating, remove all packaging material and check for any damage that may have occurred during shipping.
  • DO NOT operate any product with a damaged cord or plug.
  • DO NOT use an extension cord with this appliance.
  • DO NOT run power cords under carpeting, or cover them with rugs or runners. Keep the cord away from areas where it may be tripped over.
  • Always unplug the dehumidifier before emptying the water tank.
  • The water collected in the tank must be discarded. The water should never be used for drinking.
  • Always unplug the dehumidifier and remove the water from the water tank before cleaning, servicing, or relocating the unit.
  • Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug-end only; never pull the cord.
  • This appliance has been manufactured for use in domestic environments and must not be used for other purposes.
  • DO NOT use the product in areas where gasoline, paint, or other flammable goods and objects are used or stored.
  • This dehumidifier is designed for indoor residential applications only. It should not be used for commercial or industrial applications.
  • DO NOT attempt to repair or adjust any electrical or mechanical functions of the dehumidifier, as this may cause danger and void the warranty.
  • DO NOT cover the air inlet or outlet on the appliance, as this may cause the unit to fail.
  • DO NOT insert or allow objects to enter any ventilation or exhaust opening, as this may damage the product and could cause electrical shock or fire.
  • DO NOT let children play with this appliance, packaging, or the included plastic bag.
  • If the unit is damaged or it malfunctions, do not continue to operate it. Unplug the product from the electrical outlet. Refer to the troubleshooting section and contact the customer support center.
  • Always place the dehumidifier on a leveled floor.
  • Never install the product near a bathtub or any water container.
  • Store in a dry area, away from direct sunlight, when not in use.
  • This appliance and its packaging materials are not intended for use by persons (including children or the elderly) with reduced physical, sensory, or mental capabilities, or a lack of experience and knowledge, unless they have been given supervision or instructions concerning the use of the appliance by a person responsible for their safety.
  • Always grip the top handle and keep the unit upright when transporting from room to room – DO NOT tilt the product on its side or upside-down.
  • If the dehumidifier was transported tilted on its side, you must position it upright again and wait at least 4 hours before using it.
  • WARNING: To reduce the risk of fire or electric shock, do not use this appliance with any solid-state speed control device.

HOW A DEHUMIDIFIER WORKS

When the dehumidifier is switched ON, a fan pulls moisture-laden air into the dehumidifier, where it passes through dehumidifying coils inside the unit. These coils condense moisture from the air and collect it in the water tank. The dry air is then exhausted from the dehumidifier. The air flows through the air vents of the dehumidifier into the room as dry, warm air.

IMPORTANT: The dehumidifier is designed to operate between 41°F (5°C) and 89°F (32°C). The dehumidifier’s performance may be greatly reduced if the room temperature is beyond this temperature range.

UNPACKAGING THE DEHUMIDIFIER

  • This Dehumidifier is packaged with a colored or transparent tape to secure some parts during transportation. Remove the colored or transparent packaging tape from the unit.
  1. Gently pull the water tank out of the dehumidifier.
  2. Remove the splash guard from the top part of the water tank.
  3. Take out the power plug, drain hose, and other accessories, which are placed inside the tank of the dehumidifier.
  4. Once all accessories have been removed, replace the splash guard onto the top part of the water tank. Make sure that the tank is properly positioned.

There is a Foam Float inside the water tank that senses the water level to automatically stop dehumidification when the water tank is full. Make sure the Foam Float is positioned correctly inside the water tank by ensuring it lies level with the top edge of the water tank.

DO NOT REMOVE THE FOAM FLOAT.

PARTS DESCRIPTIONHoneywell TP70PWKNR 50 Pint Energy Star Dehumidifier with Pump-1

  1. Control Panel
  2. Handle
  3. LED Display
  4. Splash Guard
  5. Water Tank Handle
  6. Foam Float
  7. Water Tank
  8. Water Level Indicator
  9. Casters
  10. Dehumidified Air Exhaust Vent
  11. Washable Dust Filter
  12. Direct Drain Outlet
  13. Direct Drain Cap
  14. Mounting Holes for Cord Winders
  15. Power Cord & Plug
  16. Cord Winders
  17. Continuous Water Drain Tube
  18. Continuous Water Drain Cap
  19. Auto Drain Pump Tube
  20. Auto Drain Pump Cap

THIS IS ONLY FOR MODEL TP55PN / TP70P / TP70PN WITH BUILT-IN DRAIN PUMP

INSTALL THE CORD WINDER

Once you have removed the cord winder accessories from the water tank, follow the steps below.

  • Step 1: Line up the cord winder pieces with the mounting holes.
  • Step 2: Rotate 45 degrees clockwise.
  • Step 3: Once you hear “click”, then you know the cord winder is ready for use.

NOTE: Once the installation of the cord winder has been completed. The cord winder cannot be removed. The installation is permanent.

USE & OPERATION

CONTROL PANELHoneywell TP70PWKNR 50 Pint Energy Star Dehumidifier with Pump-2

  1. Display Screen
  2. Power Control
  3. Humidity / Timer Set Controls
  4. Fan Speed Control
  5. Timer Control
  6. Filter Alert
  7. Sleep Mode
  8. Water Full Indicator Light
  9. Continuous Operation Light
  10. PTC Mode
  11. Auto Drain Pump Mode

FUNCTION BUTTONS

POWER CONTROL

Press POWER CONTROL to switch the dehumidifier ON or OFF.

HUMIDITY CONTROL SETTING

When the unit is switched ON, the Display Screen shows the current humidity percentage. Press or to select your preferred humidity level. The humidity is adjusted in increments of 5% by pressing + or –. The adjustable Relative Humidity (RH) range is between 30% RH to 90% RH. Ten seconds after setting the preferred humidity setting, the display will revert to displaying the current humidity.

Recommended Settings: It is recommended to leave the unit running at 30% humidity at High Fan Speed during the first 2 to 3 days until damp odors are removed. After a few days, when the Relative Humidity has been reduced to a more comfortable level, press + or – to choose a higher RH% that maintains a comfortable humidity level thereafter. A recommended healthy humidity level is between 40% and 50%.

NOTE: The humidity sensor senses current humidity in the surrounding area. It is normal for a few degrees of variance in the humidity sensitivity of the sensor.

CONTINUOUS MODE

To activate the Continuous Mode, press the – button on the Display Screen until CO appears. The indicator light will be illuminated. The unit will run continuously.

WATER TANK FULL ALERT

When the Water Tank is full, the indicator will be illuminated. The unit will beep for 3 seconds. The compressor will shut off, and the fan will stop for a few minutes. To switch off the indicator light, empty the water tank, and when replacing it, ensure the tank is secured properly in place.

IMPORTANT: Do not place the Water Tank on the floor when full. In case of an uneven base, which may cause the tank to spillover.

TIMER CONTROL

The dehumidifier can be set to automatically switch ON or OFF for a selected period of time (between 0.5-24 hours intervals). The Timer hours selection is displayed on the Display Screen.

NOTE: Before setting the Timer control, make sure there is power to the unit.

FAN SPEED CONTROL

There are two fan speeds – High and Low. When the indicator light is illuminated, the unit is operating on High speed. When the indicator light is off, and the unit is on, the unit is operating on Low speed.

FILTER ALERT

When the Filter Alert Light is ON, it is time to clean the filter. Switch the unit OFF and carefully remove the filter from the unit and clean it. Replace the filter and switch ON the unit.

The Filter Alert Light should not be illuminated until the filter requires cleaning again. The frequency of filter cleaning depends on the room environment conditions. Some rooms may require changing more frequently than others.

SLEEP MODE

The LED display brightness will be reduced when the unit is in Sleep Mode. Press the SLEEP MODE button to activate the Sleep Mode. When Sleep Mode is activated, the indicator light will be illuminated. There is a one-minute window period in which you can adjust the settings, such as humidity and fan speed.

After one minute has lapsed, the top display will shut off, except the indicator light. Press any button to deactivate Sleep Mode.

PTC HEATER MODE

Press the PTC HEATER MODE button to activate PTC Heater Mode, the indicator light is illuminated. The PTC Heater function is suitable for environments with a temperature of 0°F to 41°F (0°C to 5°C). This technology helps to add heat to the dehumidifying process, which helps to improve the efficiency and increases the dehumidifying capacity of the unit.

THIS IS ONLY FOR MODEL TP50H / TP50HN WITH PTC TECHNOLOGY

AUTO DRAIN PUMP MODE

The Auto Drain Pump function helps to remove condensation vertically and horizontally. Press the AUTO DRAIN PUMP MODE button to activate the Pump function, the indicator light will be illuminated.

THIS IS ONLY FOR MODEL TP55PN / TP70P / TP70PN WITH BUILT-IN DRAIN PUMP

AUTO RESTART FUNCTION

This unit is equipped with an Auto Restart feature. When there is a power outage, the dehumidifier will automatically resume all its previous settings upon regaining power.

AUTOMATIC DEFROST

Frost may build up on the internal coils of the unit. When there is frost buildup, the internal compressor will turn off, and the fan will continue to run until the frost has melted. Once the internal coils have defrosted and dried, the compressor or fan will automatically restart, and dehumidifying will resume.

DRAINING THE WATER

WARNING: Always drain and discard water collected from dehumidification. The water is not clean and cannot be used for drinking.

Draining water collected in the Water Tank

The condensed water can be collected directly into the water tank. When the water tank is full, the dehumidifier will automatically shut OFF and the indicator will illuminate on the control panel, followed by a beeping sound.

IMPORTANT: Do not move the dehumidifier when the Water Tank is full, as it will be heavy and can cause water spillage.

  • Locate the water tank at the front of the dehumidifier. Gently pull the water tank out.
  • Grip the handle inside the water tank and carry the water tank to a sink to empty.
  • Replace the empty water tank back into the front of the dehumidifier. Please make sure that the tank is properly positioned. The safety feature ensures that any misalignment of the tank and the unit will prevent the unit from turning back on.Honeywell TP70PWKNR 50 Pint Energy Star Dehumidifier with Pump-3

IMPORTANT: Improper alignment or positioning of the water tank will cause the unit to pause operation, the warning light on top of the dehumidifier will illuminate, followed by a beeping sound, until the water tank is fitted properly.

NOTE: There is a Foam Float inside the water tank that senses the water level to automatically stop dehumidification when the water tank is full. Make sure the Foam Float is positioned correctly inside the water tank by ensuring it lies level with the top edge of the water tank.

Continuous Water Drainage – Using a Continuous Water Drain Tube

A continuous water drain tube is included with this unit. To activate the continuous water draining function, you will require a suitable water drain (e.g., sink or drain hole at floor level) near the dehumidifier.

NOTE: The Continuous Drain Tube and Continuous Drain Cap come pre-installed.

  • Locate the drain outlet at the back of the unit. Unscrew and remove the Direct Drain Cap. Insert and screw the Continuous Water Drain Tube into the Direct Drain Outlet.
  • If there are leaks, the Continuous Water Drain Tube and Cap may have loosened and may not be connected properly. Disconnect, replace, and tighten again.
  • Position the other end of the Continuous Water Drain Tube in the sink or drain. Make sure the tube is not bent or kinked, which might stop the water flow. Make sure the tube is secured over the drain and will not fall out of place, causing unwanted water spillage.

IMPORTANT: Make sure water can flow down the Continuous Water Drain Tube by keeping the tube angled down and free of bends or kinks.

IMPORTANT: If the unit is placed on uneven ground or the Drain Tube is installed incorrectly, the water may fill the water tank and stop running. Please check whether the ground is uneven and reinstall the Drain Tube.

Continuous Water Drainage – Using the Auto Drain Pump option

THIS IS ONLY FOR MODEL TP55PN / TP70P / TP70PN WITH BUILT-IN DRAIN PUMP

The Auto Drain Pump is available if you want to use the continuous drain function, but the drain is further away or located above the dehumidifier. The Auto Drain Pump Tube can be attached to the Direct Drain Outlet located on the back side of the dehumidifier. When the water level in the water tank reaches a certain level, the drain pump will automatically pump the water out of the tank to the drain. This allows you to drain water condensation vertically or horizontally, even if the drain is located above the dehumidifier.

NOTE: The Auto Drain Pump Tube and Auto Drain Pump Cap come pre-installed.

  • Locate the drain outlet at the back of the unit. Unscrew and remove the Direct Drain Cap. Insert and screw the Auto Drain Pump Tube into the Direct Drain Outlet.
  • If there are leaks, the Auto Drain Pump Tube and Auto Drain Pump Cap may have loosened and may not be connected properly. Disconnect, replace, and tighten again.
  • To activate the Pump function, press the indicator. Once on, the indicator light will be illuminated.
  • Place the other end of the tube into the sink or drain. The water can be pumped up to 16.4 ft (5 m) vertically or horizontally.

NOTE: DO NOT use an alternative drain tube that is longer than the one provided with the unit.

CLEANING & MAINTENANCE

WARNING: Always switch OFF the dehumidifier and unplug it from the electrical outlet before attempting any cleaning or maintenance of this product.

Appliance Maintenance:

  • Switch OFF the appliance before disconnecting the power supply.
  • Only use a soft cloth to clean the appliance.

Dust Filter Maintenance:

The Dust Filter located at the back of the unit helps to remove dust particles from the air. A dirty filter clogged by dust particles can reduce the efficiency of the dehumidifier. For optimum dehumidification, it is recommended to clean the dust filter every 2 weeks:

  1. Switch off and unplug the dehumidifier from the electrical outlet.
  2. Carefully pull out the dust filter from the dehumidifier.
  3. Rinse the dust filter under running water, or vacuum away the dust with a vacuum cleaner.
  4. After cleaning the dust filter, dry it in a cool, shaded place, then carefully reinstall it into the unit.

TROUBLESHOOTING GUIDE

The following troubleshooting guide addresses the most common problems. If problems persist, call customer service.Honeywell TP70PWKNR 50 Pint Energy Star Dehumidifier with Pump-4

Honeywell TP70PWKNR 50 Pint Energy Star Dehumidifier with Pump-5

Honeywell TP70PWKNR 50 Pint Energy Star Dehumidifier with Pump-6

Honeywell TP70PWKNR 50 Pint Energy Star Dehumidifier with Pump-7

For more Manuals by Honeywell, visit ManualsLibraryy

Honeywell TP70PWKNR 50 Pint Energy Star Dehumidifier with Pump-FAQs

Why does my Honeywell dehumidifier run constantly?

If your dehumidifier runs non-stop, the air filter may be dirty or clogged. Clean or replace it to restore proper airflow and help it reach the set humidity level.

What is the warranty on the Honeywell TP70PWKNR dehumidifier?

All Honeywell dehumidifiers, including the TP70PWKNR, come with a 5-year extended warranty for peace of mind.

What humidity level should I set my dehumidifier to?

The ideal humidity setting is between 40–60%, with 45–55% being the most comfortable for most homes.

Does the fan run all the time on this dehumidifier?

No, most models automatically turn the fan off once the desired humidity is reached, saving energy.

How much electricity does the Honeywell dehumidifier use?

This unit uses about 0.48 kWh, making it energy-efficient compared to other household appliances.

Will the dehumidifier shut off automatically?

Yes, it will automatically turn off once your set humidity level is reached.

What is Comfort Mode on my dehumidifier?

In Comfort Mode, the unit maintains humidity between 45–55%, adjusting based on the room temperature for optimal comfort.

Is the Honeywell TP70PWKNR a reliable unit?

Yes, it’s ENERGY STAR Most Efficient Certified and known for its dependable performance with lower energy use.

How long does a Honeywell dehumidifier last?

With proper care, it typically lasts 3–5 years, and in some cases up to 8 years.

What temperature range does the dehumidifier work in?

It operates best between 41°F to 90°F. Below 41°F, its performance may decline due to risk of internal freezing.